Schneider ac magnetic contactor LC1D115M7
115A 220VAC 3P
Range of product | TeSys D |
Product or component type |
Contactor |
Device short name |
LC1D |
Contactor application |
Motor control |
Resistive load | |
Utilisation category |
AC-1 |
AC-3 | |
Poles description |
3P |
Power pole contact composition |
3 NO |
[Ue] rated operational voltage |
<= 300 V DC for power circuit |
<= 1000 V AC 25...400 Hz for power circuit | |
[Ie] rated operational current |
115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit |
200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit | |
Motor power kW |
65 kW at 1000 V AC 50/60 Hz |
80 kW at 660...690 V AC 50/60 Hz | |
75 kW at 500 V AC 50/60 Hz | |
59 kW at 415...440 V AC 50/60 Hz | |
55 kW at 380...400 V AC 50/60 Hz | |
30 kW at 220...230 V AC 50/60 Hz | |
Motor power HP (UL / CSA) |
100 hp at 575/600 V AC 50/60 Hz for 3 phases motors |
75 hp at 460/480 V AC 50/60 Hz for 3 phases motors | |
40 hp at 230/240 V AC 50/60 Hz for 3 phases motors | |
30 hp at 200/208 V AC 50/60 Hz for 3 phases motors | |
Control circuit type |
AC 50/60 Hz |
Control circuit voltage |
220 V AC 50/60 Hz |
Auxiliary contact composition |
1 NO + 1 NC |
[Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947 |
Overvoltage category | III |
[Ith] conventional free air thermal current |
200 A at <= 60 °C for power circuit |
Irms rated making capacity |
1260 A at 440 V for power circuit conforming to IEC 60947 |
250 A DC for signalling circuit conforming to IEC 60947-5-1 | |
140 A AC for signalling circuit conforming to IEC 60947-5-1 | |
Rated breaking capacity |
1100 A at 440 V for power circuit conforming to IEC 60947 |
[Icw] rated short-time withstand current |
140 A 100 ms signalling circuit |
120 A 500 ms signalling circuit | |
100 A 1 s signalling circuit | |
1100 A <= 40 °C 1 s power circuit | |
950 A <= 40 °C 10 s power circuit | |
550 A <= 40 °C 1 min power circuit | |
250 A <= 40 °C 10 min power circuit | |
Associated fuse rating |
10 A gG for signalling circuit |
200 A gG at <= 690 V coordination type 2 for power circuit | |
250 A gG at <= 690 V coordination type 1 for power circuit | |
Average impedance |
0.60 mOhm at 50 Hz - Ith 200 A for power circuit |
[Ui] rated insulation voltage |
1000 V for power circuit conforming to IEC 60947-4-1 |
600 V for signalling circuit certifications UL | |
600 V for signalling circuit certifications CSA | |
690 V for signalling circuit conforming to IEC 60947-1 | |
600 V for power circuit certifications UL | |
600 V for power circuit certifications CSA | |
Electrical durability |
0.95 Mcycles 115 A AC-3 at Ue <= 440 V |
0.8 Mcycles 200 A AC-1 at Ue <= 440 V | |
Power dissipation per pole |
7.9 W AC-3 |
24 W AC-1 | |
Safety cover |
With |
Mounting support |
Plate |
Rail | |
Standards |
EN 60947-4-1 |
EN 60947-5-1 | |
IEC 60947-4-1 | |
IEC 60947-5-1 | |
UL 508 | |
CSA C22.2 No 14 | |
Product certifications |
BV |
CCC | |
CSA | |
DNV | |
GL | |
GOST | |
RINA | |
UL | |
LROS | |
Connections - terminals |
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: solid - without cable end |
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: solid - without cable end | |
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - with cable end | |
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - with cable end | |
Power circuit: connector 2 cable(s) 10...50 mm² - cable stiffness: flexible - without cable end | |
Power circuit: connector 1 cable(s) 10...120 mm² - cable stiffness: flexible - without cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: solid - without cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - without cable end | |
Control circuit: screw clamp terminals 1 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end | |
Control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end | |
Tightening torque |
Power circuit: 12 N.m - on connector hexagonal 4 mm |
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 | |
Control circuit: 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm | |
Operating time |
20...50 ms closing |
6...20 ms opening | |
Safety reliability level |
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 | |
Mechanical durability | 8 Mcycles |
Operating rate |
2400 cyc/h at <= 60 °C |
FAQ
Q1: Do you have a catalogue? Can you send me the catalogue to have a check of all your product ?
Yes , We have product catalogs. Please inform your requested brand, model, then we will reply by on line or Email to sending the catalog.
Q2: I need your price list of all your products, do you have a price list ?
Please inform exactly brand, series or specification, then we will try to our best to provide price list of products. Because we have so many items, and need to focus your requested. If you don't have modes, we also can provide catalog for reference.
If you want to check any price of our products, please contact us.We will send offer to you soon!
Q3: What kind of payment do you accept ?
We accept T/T, Paypal, Western Union, Alibaba trade assurance and etc. Please contact us and our salesmen will reply your exactly payment way. Hope we can create a better business relationship with you.
Q4: I can’t assure the models of product from catalog, can you choose models for me?
We are the Schneider Distributor in Taiwan, you can get our service at quotation, technique consult, ,ex-stock products, after sales service and etc.
So you can provide specification let us check.
Q5: How to ship my order ? Is it safe?
For small package, we will send it by Express, such as DHL, FedEx, TNT, EMS, OCS. SF. That’s a Door to Door service.
For big packages, we will send them by Air or by sea.We will use good packing and ensure the goods safety.
For big packages, we will send them by Air or by sea.We will use good packing and ensure the goods safety.
Certifications
Packing & Delivery
Our Company
http://www.tw-rstpower.com/